Features: | Fiberglass rectangle tube | |
High strength light weight: | Easy to transportation | |
Corrosion resistant: | Never rot,rust or corrode | |
Fire-retardant and Non-conductive: | Helps to create a safer environment | |
Dimensionally stable: | Won't shrink,swell,warp or bow | |
Virtually maintenance-free: | Durable and weather-resistant for a longer life | |
Easy to fabricate and install: | Can be cut,drilled and assembled with standard tools | |
Non-leaching: | Does not require environmentally hazardous preservatives | |
Testing results for physical properties: | ||||||
Testing Items | Unit | Testing results | Testing standard | |||
Density | g/cm3 | 1.85-1.9 | ASTM D792 | |||
Water absorption | % | 0.57 | ASTM D570 | |||
Flexural strength | MPa | 302 | ASTM D790 | |||
Flexural modulus | Gpa | 18.6 | ASTM D790 | |||
Tensile strength | Mpa | 210 | ASTM D638 | |||
Tensile modulus | Gpa | 22 | ASTM 638 | |||
Flame retardant rating | V0/V1 | UL94 | ||||
Dielectric breakdown voltage | KV | 14.98 | ASTM D149-09 | |||
Notes: The above testing results are based on ordinary materials,if any special requirements,please feel free to contact us. | ||||||